Simplified IAQ calculation with the Bosch bme680

raspi-bme680-iaq implements a basic indoor air quality (IAQ) calculation using the VOC sensitive gas resistance of the Bosch BME680 sensor, circumventing the closed source Bosch BSEC library.

The IAQ calculation as a percentage value is inspired by the example in the pimoroni bme680 library, where higher percentage values represent higher air quality. In contrast, the BSEC library returns an IAQ value between 0 and 500, where lower values represent higher air quality.

How to use

The IAQTracker utilizes the bme data structure defined in the pimoroni driver library. It also uses the sensor class defined therein for communication with a BME680 sensor.

On Initialization, the tracker can be handed three parameters:

The tracker is updated on every call of getIAQ. As long a the number of burn_in_cycles is not yet reached, the return-value will be of None type. Afterwards, it will return the IAQ value on a scale between 0 and 100.

IAQ calculation

For IAQ calculation, the gas resistance R_gas, the ralative humidity hum and the temperatur temp are used from the input measurement object. The latter two are used in calculating the absolute humidity

hum_abs = hum * 10 * rho_max

in g/m^3. The calculation of the maximum absolute water density

rho_max = (6.112 * 100 * np.exp((17.62 * temp)/(243.12 + temp)))/(461.52 * (temp + 273.15))

is derived from the ideal gas law and the Magnus equation.

Using the hum_abs the influence of the present water vapor concentration on the gas resistance can be compensated. The dependency appears to be exponential. Thus, the bare VOC resistance is obtained by

comp_gas = R_gas * np.exp(ph_slope * hum_abs).

The air quality AQ is calculated as the ratio between comp_gas and the ceiling value gas_ceil, which is further squared for a steeper slope at higher air qualities and capped at 100%:

AQ = np.minimum((comp_gas / gas_ceil)**2, 1) * 100.

Humidity Slope Calibration

The exact value of the slope for humidity compensation, ph_slope, appears to depend on the heating profile (time and temperature) as well as the polling frequency and even may vary between individual sensors. However, it is easily determined from a plot of the logarithm of the raw gas resistance np.log(R_gas) over the absolute humidity hum_abs, like shown below.

logarithm of gas resistance plotted over absolute humidity

Calibration data can be aquired by measuring over some period in rooms with clean air and open windows, as well as in front of a windows or even outside. I obtained further data by spraying the surrounding air with a water spray bottle to reach into humidities close to 100%. Note, that the humidity readings of the bme680 decay only slowly and may lag behind a rapidly dropping humidity. this can be seen by the lower branch of data points for high humidities in the plot above. The value of ph_slope is determined from the above plot by fitting a line through all valid data points. This cen be done either manually or by linear regression.

Physical Background

The BME680 datasheet states in Sec. 4.2

The BME680 is a metal oxide-based sensor that detects VOCs by adsorption (and subsequent oxidation/reduction) on its sensitive layer.

The sensor measures the electrical resistance of the metal-oxide surface by applying a voltage to it. Through heating the oxide layer activation energy is provided for reactions with air compounds. These reactions lead to a reduction in resistance which then can be measured.

By researching the web on such types of sensors it becomes apparent that most of them have an exponential response to the concentration of VOCs. It is most commonly tested and calibrated with ethanole vapors. Further, the response to a given type of VOC depends strongly on the specific choice of metal oxide as well as the micro-structuring of the surface (see this article for a detailed review). Moreover, some sensors are also reactive towards water molecules, which is also the case for the BME680, as described later in Sec. 4.2 of the BME680 datasheet. The choice on how to process the gas resistance readings was informed by these insights.

From the literature it also becomes apparant, that the response to different VOCs is temperature dependent. Hence, polling the BME680 at different heating profiles (which cen easily be switched by the build-in registers) could allow the extraction of further information about the air compounds. However, this would require the knowledge of the exact reaction curves (that Bosch for sure will keep secret) or access to a controlled measuring chamber.

Remarks

This is a list of oddities and things to consider I noticed during testing the BME680.