Home

Awesome

Exometer - Erlang instrumentation package

Copyright (c) 2014 Basho Technologies, Inc. All Rights Reserved.

Version: Feb 1 2015 23:02:37

Authors: Ulf Wiger (ulf.wiger@feuerlabs.com), Magnus Feuer (magnus.feuer@feuerlabs.com).

Build Status

NOTE: Exometer has been split into exometer_core, and exometer (as well as separate reporter applications). The latest monolithic version of Exometer is 1.1.

The Exometer package allows for easy and efficient instrumentation of Erlang code, allowing crucial data on system performance to be exported to a wide variety of monitoring systems.

Exometer comes with a set of pre-defined monitor components, and can be expanded with custom components to handle new types of Metrics, as well as integration with additional external systems such as databases, load balancers, etc.

This document gives a high level overview of the Exometer system. For details, please see the documentation for individual modules, starting with exometer.

Note the section on Dependency Management for how to deal with optional packages, both users and developers.

<a name="Table_of_Content">Table of Content</a>

  1. Concept and definitions
    1. Metric
    2. Data Point
    3. Metric Type
    4. Entry Callback
    5. Probe
    6. Caching
    7. Subscriptions and Reporters
  2. Built-in entries and probes
    1. counter (exometer native)
    2. fast_counter (exometer native)
    3. gauge (exometer native)
    4. exometer_histogram (probe)
    5. exometer_uniform (probe)
    6. exometer_spiral (probe)
    7. exometer_folsom [entry]
    8. exometer_function [entry]
  3. Built in Reporters
    1. exometer_report_graphite
    2. exometer_report_opentsdb
    3. exometer_report_amqp
    4. exometer_report_snmp
  4. Instrumenting Erlang code
    1. Exometer Start
    2. Creating metrics
    3. Deleting metrics
    4. Setting metric values
    5. Retrieving metric values
    6. Setting up subscriptions
    7. Set metric options
  5. Configuring Exometer
    1. Configuring type - entry maps
    2. Configuring statically defined entries
    3. Configuring static subscriptions
    4. Configuring reporter plugins
    5. Configuring opentsdb reporter
    6. Configuring amqp reporter
    7. Configuring graphite reporter
    8. Configuring snmp reporter
  6. Creating custom exometer entries
  7. Creating custom probes
  8. Creating custom reporter plugins
  9. Dependency management

<a name="Concepts_and_Definitions">Concepts and Definitions</a>

Exometer introduces a number of concepts and definitions used throughout the documentation and the code.

Overview

<a name="Metric">Metric</a>

A metric is a specific measurement sampled inside an Erlang system and then reported to the Exometer system. An example metric would be "transactions_per_second", or "memory_usage".

Metrics are identified by a list of terms, such as given below:

[ xml_front_end, parser, file_size ]

A metric is created through a call by the code to be instrumented to exometer:new(). Once created, the metric can be updated through exometer:update(), or on its own initiative through the exometer_probe:sample behavior implementation.

<a name="Data_Point">Data Point</a>

Each metric can consist of multiple data points, where each point has a specific value.

A typical example of data points would be a transactions_per_second (tps) metric, usually stored as a histogram covering the last couple of minutes of tps samples. Such a histogram would host multiple values, such as min, max, median, mean, 50_percentile, 75_percentile, etc.

It is up to the type of the metric, and the data probe backing that type (see below), to specify which data points are available under the given metric.

<a name="Metric_Type">Metric Type</a>

The type of a metric, specified when the metric is created through exometer:new(), determines which exometer_entry callback to use.

The link between the type and the entry to use is configured through the exometer_admin module, and its associated exometer defaults configuration data.

The metric type, in other words, is mainly used to map a metric to a configurable exometer_entry callback, but it can also be referenced in queries using exometer:select/1. An entry callback can also support multiple types (the type is provided as an argument in the callback functions).

Exometer provides default mappings for a number of metric types. It is possible to select different callbacks for each metric instance, as well as modify metrics using callback-specific options. Please see Configuring type - entry maps for details on how to do this.

<a name="Entry_Callback">Entry Callback</a>

An exometer entry callback will receive values reported to a metric through the exometer:update() call and compile it into one or more data points. The entry callback can either be a counter (implemented natively in exometer), or a more complex statistical analysis such as a uniform distribution or a regular histogram.

The various outputs from these entries are reported as data points under the given metric.

An entry can also interface external analytics packages. exometer_folsom, for example, integrates with the folsom_metrics package found at https://github.com/boundary/folsom.

<a name="Probe">Probe</a>

Probes are a further specialization of exometer entries that run in their own Erlang processes and have their own state (like a gen_server). A probe is implemented through the exometer_probe behavior.

A probe can be used if independent monitoring is needed of, for example, /proc trees, network interfaces, and other subsystems that need periodic sampling. In these cases, the exometer_probe:probe_sample() call is invoked regularly by exometer, in the probe's own process, in order to extract data from the given subsystem and add it to the metric's data points.

<a name="Caching">Caching</a>

Metric and data point values are read with the exometer:get_value() function. In the case of counters, this operation is very fast. With probes, the call results in a synchronous dialog with the probe process, and the cost of serving the request depends on the probe implementation and the nature of the metric being served.

If the cost of reading the value is so high that calling the function often would result in prohibitive load, it is possible to cache the value. This is done either explicitly from the probe itself (by calling exometer_cache:write()), or by specifying the option {cache, Lifetime} for the entry. If an entry has a non-zero cache lifetime specified, the get_value() call will try fetching the cached value before calling the actual entry and automatically caching the result.

Note that if {cache, Lifetime} is not specified, exometer:get_value() will neither read nor write to the cache. It is possible for the probe to periodically cache a value regardless of how the cache lifetime is set, and the probe may also explicitly read from the cache if it isn't done automatically.

<a name="Subscriptions_and_Reporters">Subscriptions and Reporters</a>

The subscription concept, managed by exometer_report allows metrics and their data points to be sampled at given intervals and delivered to one or more recipients, which can be either an arbitrary process or a Reporter plugin.

Each subscription ties a specific metric-datapoint pair to a reporter and an interval (given in milliseconds). The reporter system will, at the given interval, send the current value of the data point to the subscribing reporter. The subscription, with all its parameters, is setup through a call to exometer_report:subscribe().

In the case of processes, subscribed-to values will be delivered as a message. Modules, which implement the exometer_report callback behavior, will receive the plugins as a callbacks within the exometer_report process.

Subscriptions can either be setup at runtime, through exometer_report:subscribe() calls, or statically through the exometer_report configuration data.

<a name="Built-in_entries_and_probes">Built-in entries and probes</a>

There are a number of built-in entries and probes shipped with the Exometer package, as described below:

<a name="counter_(exometer_native)">counter (exometer native)</a>

The counter is implemented directly in exometer to provide simple counters. A call to exometer:update() will add the provided value to the counter.

The counter can be reset to zero through exometer:reset().

The available data points under a metric using the counter entry are value and ms_since_reset.

<a name="fast_counter_(exometer_native)">fast_counter (exometer native)</a>

A fast counter implements the counter functionality, through the trace_info system, yielding a speed increase of about 3.5 in comparison to the regular counter.

The tradeoff is that running tracing and/or debugging may interfere with the counter functionality.

A call to exometer:update() will add the provided value to the counter.

The counter can be reset to zero through exometer:reset().

The available data points under a metric using the fast_counter entry are value and ms_since_reset.

<a name="gauge_(exometer_native)">gauge (exometer native)</a>

The gauge is implemented directly in exometer to provide simple gauges. A call to exometer:update() will set the gauge's value to the provided value. That is, the value of the gauge entry is always the most recently provided value.

The gauge can be reset to zero through exometer:reset().

The available data points under a metric using the gauge entry are value and ms_since_reset.

<a name="histogram_(probe)">histogram (probe)</a>

The histogram probe stores a given number of updates, provided through exometer:update(), in a histogram. The histogram maintains a log derived from all values received during a configurable time span and provides min, max, median, mean, and percentile analysis data points for the stored data.

Exometer supports a number of different histogram implementations, each with different performance and accuracy trade-offs.

In order to save memory, the histogram is divided into equal-sized time slots, where each slot spans a settable interval. All values received during a time slot will be averaged into a single value to be stored in the histogram once the time slot expires. The averaging function (which can be replaced by the caller), allows for high-frequency update metrics to have their resolution traded against resource consumption.

<a name="exometer_uniform_(probe)">exometer_uniform (probe)</a>

The uniform probe provides a uniform sample over a pool of values provided through exometer:update(). When the pool reaches its configurable max size, existing values will be replaced at random to make space for new values. Much like exometer_histogram, the uniform probe provides min, max, median, mean, and percentile analysis data points for the stored data.

<a name="exometer_spiral_(probe)">exometer_spiral (probe)</a>

The spiral probe maintains the total sum of all values stored in its histogram. The histogram has a configurable time span, all values provided to the probe, through exometer:update(), within that time span will be summed up and reported. If, for example, the histogram covers 60 seconds, the spiral probe will report the sum of all values reported during the last minute.

The grand total of all values received during the lifetime of the probe is also available.

<a name="exometer_folsom_[entry]">exometer_folsom [entry]</a>

exometer_folsom is an entry behavior which implements most metric types supported by the folsom metrics package: Specifically, the metric types counter, spiral, histogram, meter, meter_reader, gauge, duration and history.

The folsom entry integrates with the folsom metrics package provided by the boundary repo at github. Updated values sent to the folsom entry can be forwarded to folsom's counter, histogram, duration, meter, and spiral.

Folsom integration is provided as a backup. New code using Exometer should use the native probes that duplicate folsom.

<a name="exometer_function_[entry]">exometer_function [entry]</a>

The function entry allows for an existing erlang function to be wrapped as an exometer entry. The exometer_function module supports a number of options for passing arguments and matching out data points from the result.

The function entry provides an easy way of integrating an external system without having to write a complete entry.

<a name="Built_in_Reporters">Built in Reporters</a>

Exometer ships with some built-in reporters which can be used to forward updated metrics and their data points to external systems. They can also serve as templates for custom-developed reporters.

<a name="exometer_report_graphite">exometer_report_graphite</a>

The graphite reporter uses the TCP/IP protocol to forward subscribed-to metrics and data points to a graphite server, such as the one provided by http://hostedgraphite.com. When the graphite reporter receives a metric-datapoint value (subscribed to through exometer_report:subscriber()), the reporter will immediately forward the key-value pair to the graphite server.

<a name="exometer_report_opentsdb">exometer_report_opentsdb</a>

The OpenTSDB reporter sends metrics to an OpenTSDB server using the telnet API. All subscribed-to metric-datapoint values received by the reporter are immediately forwarded to OpenTSDB.

If the OpenTSDB connection is lost, the reporter will attempt to reconnect to it at a configurable interval.

The data sent to OpenTSDB will be formatted as follows:

put metric timestamp value host=host type=datapoint

Where the value for the host tag will be the configured host in the reporter configuration (defaults to the value returned by netadm:localhost), and datapoint tags as specified by the subscriber.

Please see Configuring opentsdb reporter for details on the application environment parameters listed above.

<a name="exometer_report_amqp">exometer_report_amqp</a>

The AMQP reporter sends metrics to an AMQP broker as a json-encoded payload. All subscribed-to metric-datapoint values received by the reporter are forwarded to AMQP.

If the AMQP connection is lost, the reporter will attempt to reconnect to it at a configurable interval.

The data sent to AMQP will be formatted as follows:

{
  "type":"exometer_metric",
  "body":
    {"name":"messages_per_second",
     "value":0,"timestamp":1414006826,
     "host":"testhost",
     "instance":"max"}
}

Where the value for the host tag will be the configured host in the reporter configuration (defaults to the value returned by netadm:localhost), the instance tag represents the datapoint for the metric.

Please see Configuring amqp reporter for details on the application environment parameters listed above.

<a name="exometer_report_snmp">exometer_report_snmp</a>

The SNMP reporter enables the export of metrics and their datapoints to SNMP managers. The export needs to be enabled for each metric through their options. Moreover, SNMP notifications can be created using the options to send periodic reports on datapoints to SNMP managers. All SNMP protocol handling is done by the snmp application shipped with Erlang/OTP. Thus, the snmp application needs to be started and the local SNMP master agent needs to be configured correctly for SNMP export to work properly.

To configure SNMP export for a single metric use these options:

Please see Configuring snmp reporter for details on how to configure the SNMP reporter.

<a name="Instrumenting_Erlang_code">Instrumenting Erlang code</a>

The code using Exometer needs to be instrumented in order to setup and use metrics reporting.

<a name="Exometer_Start">Exometer Start</a>

The system using Exometer must start the exometer application prior to using it:


application:start(lager),
application:start(exometer).

Note that dependent applications need to be started first. On newer OTP versions (R16B or later), you can use application:ensure_all_started(exometer).

For testing, you can also use exometer:start/0.

If you make use of e.g. folsom metrics, you also need to start folsom. Exometer will not do that automatically, nor does it contain an application dependency for it.

See Configuring Exometer for details on configuration data format.

<a name="Creating_metrics">Creating metrics</a>

A metric, can be created through a call to


exometer:new(Name, Type)

Name is a list of atoms, uniquely identifying the metric created. The type of the metric, specified by Type will be mapped to an exometer entry through the table maintained by exometer_admin Please see the Configuring type - entry maps for details.

The resolved entry to use will determine the data points available under the given metric.

<a name="Deleting_metrics">Deleting metrics</a>

A metric previously created with exometer:new() can be deleted by exometer:delete().

All subscriptions to the deleted metrics will be cancelled.

<a name="Setting_metric_values">Setting metric values</a>

A created metric can have its value updated through the exometer:update() function:


exometer:update(Name, Value)

The Name parameter is the same atom list provided to a previous exometer:new() call. The Value is an arbitrarty element that is forwarded to the exometer:update() function of the entry/probe that the metric is mapped to.

The receiving entry/probe will process the provided value and modify its data points accordingly.

<a name="Retrieving_metric_values">Retrieving metric values</a>

Exometer-using code can at any time retrieve the data point values associated with a previously created metric. In order to find out which data points are available for a metric, the following call can be used:


exometer:info(Name, datapoints)

The Name parameter is the same atom list provided to a previous exometer:new() call. The call will return a list of data point atoms that can then be provided to exometer:get_value() to retrieve their actual value:


exometer:get_value(Name, DataPoint)

The Name paramer identifies the metric, and DataPoints identifies the data points (returned from the previous info() call) to retrieve the value for.

If no DataPoints are provided, the values of a default list of data points, determined by the backing entry / probe, will be returned.

<a name="Setting_up_subscriptions">Setting up subscriptions</a>

A subscription can either be statically configured, or dynamically setup from within the code using Exometer. For details on statically configured subscriptions, please see Configuring static subscriptions.

A dynamic subscription can be setup with the following call:


exometer_report:subscribe(Recipient, Metric, DataPoint, Inteval)

Recipient is the name of a reporter.

<a name="Set_metric_options">Set metric options</a>

Each created metric can have options setup for it through the following call:


exometer:setopts(Name, Options)

The Name paramer identifies the metric to set the options for, and Options is a proplist ([{ Key, Value },...]) with the options to be set.

Exometer looks up the the backing entry that hosts the metric with the given Name, and will invoke the entry's setopts/4 function to set the actual options. Please see the setopts/4 function for the various entries for details.

<a name="Configuring_Exometer">Configuring Exometer</a>

Exometer defaults can be changed either through OTP application environment variables or through the use of Basho's cuttlefish (https://github.com/basho/cuttlefish).

<a name="Configuring_type_-_entry_maps">Configuring type - entry maps</a>

The dynamic method of configuring defaults for exometer entries is:


exometer_admin:set_default(NamePattern, Type, Default)

Where NamePattern is a list of terms describing what is essentially a name prefix with optional wildcards ('_'). A pattern that matches any legal name is ['_'].

Type is an atom defining a type of metric. The types already known to exometer, counter, fast_counter, ticker, uniform, histogram, spiral, netlink, and probe may be redefined, but other types can be described as well.

Default is either an #exometer_entry{} record (unlikely), or a list of {Key, Value} options, where the keys correspond to #exometer_entry record attribute names. The following attributes make sense to preset:


{module, atom()}              % the callback module
{status, enabled | disabled}  % operational status of the entry
{cache, non_neg_integer()}    % cache lifetime (ms)
{options, [{atom(), any()}]}  % entry-specific options

Below is an example, from exometer/priv/app.config:


{exometer, [
    {defaults, [
        {['_'], function , [{module, exometer_function}]},
        {['_'], counter  , [{module, exometer}]},
        {['_'], histogram, [{module, exometer_histogram}]},
        {['_'], spiral   , [{module, exometer_spiral}]},
        {['_'], duration , [{module, exometer_folsom}]},
        {['_'], meter    , [{module, exometer_folsom}]},
        {['_'], gauge    , [{module, exometer_folsom}]}
    ]}
]}

In systems that use CuttleFish, the file exometer/priv/exometer.schema contains a schema for default settings. The setup corresponding to the above defaults would be as follows:


exometer.template.function.module  = exometer_function
exometer.template.counter.module   = exometer
exometer.template.histogram.module = exometer_histogram
exometer.template.spiral.module    = exometer_spiral
exometer.template.duration.module  = exometer_folsom
exometer.template.meter.module     = exometer_folsom
exometer.template.gauge.module     = exometer_folsom

<a name="Configuring_statically_defined_entries">Configuring statically defined entries</a>

Using the exometer environment variable predefined, entries can be added at application startup. The variable should have one of the following values:

The list of instructions may include:

Exometer will also scan all loaded applications for the environment variables exometer_defaults and exometer_predefined, and process as above. If an application is loaded and started after exometer has started, it may call the function exometer:register_application() or exometer:register_application(App). This function will do nothing if exometer isn't already running, and otherwise process the exometer_defaults and exometer_predefined variables as above. The function can also be called during upgrade, as it will re-apply the settings each time.

<a name="Configuring_static_subscriptions">Configuring static subscriptions</a>

Static subscriptions, which are automatically setup at exometer startup without having to invoke exometer_report:subscribe(), are configured through the report sub section under exometer.

Below is an example, from exometer/priv/app.config:


{exometer, [
    {report, [
        {subscribers, [
            {exometer_report_collectd, [db, cache, hits], mean, 2000, true},
            {exometer_report_collectd, [db, cache, hits], max, 5000, false}
        ]}
    ]}
]}

The report section configures static subscriptions and reporter plugins. See Configuring reporter plugins for details on how to configure individual plugins.

The subscribers sub-section contains all static subscriptions to be setup att exometer applications start. Each tuple in the prop list should be of one of the following formats:

In the case of {apply, M, F, A}, the result of apply(M, F, A) must be a list of subscribers tuples.

In the case of {select, Expr}, a list of metrics is fetched using exometer:select(MatchPattern), where the result must be on the form {Key, Type, Status} (i.e. what corresponds to '$_'). The rest of the items will be applied to each of the matching entries.

The meaning of the above tuple elements is:

Example configuration in sys.config, using the {select, Expr} pattern:


[
 {exometer, [
             {predefined,
              [{[a,1], counter, []},
               {[a,2], counter, []},
               {[b,1], counter, []},
               {[c,1], counter, []}]},
             {report,
              [
               {reporters,
                [{exometer_report_tty, []}]},
               {subscribers,
                [{select, {[{ {[a,'_'],'_','_'}, [], ['$_']}],
                           exometer_report_tty, value, 1000}}]}
              ]}
            ]}
].

This will activate a subscription on [a,1] and [a,2] in the exometer_report_tty reporter, firing once per second.

<a name="Configuring_reporter_plugins">Configuring reporter plugins</a>

The various reporter plugins to be loaded by exometer are configured in the report section under reporters

Each reporter has an entry named after its module, and the content of that entry is dependent on the reporter itself. The following chapters specifies the configuration parameters for the reporters shipped with exometer.

<a name="Configuring_opentsdb_reporter">Configuring opentsdb reporter</a>

Below is an example of the opentsdb reporter application environment, with its correct location in the hierarchy:


{exometer, [
    {report, [
        {reporters, [
            {exometer_report_opentsdb, [
                {reconnect_interval, 10},
                {connect_timeout, 8000},
                {hostname, "testhost"},
                {host, {"127.0.0.1", 4242}}
            ]}
        ]}
    ]}
]}

The following attributes are available for configuration:

<a name="Configuring_amqp_reporter">Configuring amqp reporter</a>

Below is an example of the amqp reporter application environment, with its correct location in the hierarchy:


{exometer, [
    {report, [
        {reporters, [
            {exometer_report_amqp, [
                {reconnect_interval, 10},
                {hostname, "testhost"},
                {amqp_url, "amqp://user:pass@host:5672/%2f"},
		{exchange, "metrics"},
		{routing_key, "metrics"},
		{buffer_size, 0}
            ]}
        ]}
    ]}
]}

The following attributes are available for configuration:

<a name="Configuring_graphite_reporter">Configuring graphite reporter</a>

Below is an example of the a graphite reporter application environment, with its correct location in the hierarchy:


{exometer, [
    {report, [
        {reporters, [
            {exometer_report_graphite, [
                {connect_timeout, 5000},
                {prefix, "web_stats"},
                {host, "carbon.hostedgraphite.com"},
                {port, 2003},
                {api_key, "267d121c-8387-459a-9326-000000000000"}
            ]}
        ]}
    ]}
]}

The following attributes are available for configuration:

If prefix is not specified, but api_key is, each metrics will be reported as ApiKey.Metric.

If prefix is specified, but api_key is not, each metrics will be reported as Prefix.Metric.

if neither prefix or api_key is specified, each metric will be reported simply as Metric.

<a name="Configuring_snmp_reporter">Configuring snmp reporter</a>

Below is an example of the a snmp reporter application environment, with its correct location in the hierarchy:


{exometer, [
    {report, [
        {reporters, [
            {exometer_report_snmp, [
                {mib_template, "priv/MYORG-EXOMETER-METRICS.mib"},
                {mib_dir, "/tmp/exometer"}
            ]}
        ]}
    ]}
]}

The following attributes are available for configuration:

<a name="Creating_custom_exometer_entries">Creating custom exometer entries</a>

Please see @see exometer_entry documentation for details.

<a name="Creating_custom_probes">Creating custom probes</a>

Please see @see exometer_probe documentation for details.

<a name="Creating_custom_reporter_plugins">Creating custom reporter plugins</a>

Please see @see exometer_report documentation for details.

<a name="Dependency_management">Dependency management</a>

Exometer dependencies can be controlled using the EXOMETER_PACKAGES unix environment variable: a string listing packages or applications to either keep or remove, separated using space, tab or comma.

<a name="Syntax">Syntax</a>

<a name="Supported_packages">Supported packages</a>

Example - use only basic deps plus afunix

   EXOMETER_PACKAGES="(basic), +afunix" make

Example - use all deps except the AMQP-related deps:

   export EXOMETER_PACKAGES="(full) -(amqp)"

<a name="Conditional_defines">Conditional defines</a>

For each optional dependency that is included, a macro is defined, named dep_App - e.g. dep_afunix. Developers must not include compile-time dependencies to optional applications, without checking the corresponding macro and ensuring that the module compiles even when the dependent application is not included. See exometer_report_amqp.erl for an example.

<a name="Customizing_rebar.config">Customizing rebar.config</a>

The OS environment variables EXOMETER_CONFIG_PREPROCESS and EXOMETER_CONFIG_POSTPROCESS can be used to insert a script, similar to rebar.config.script in the processing flow of the exometer build.

As the names imply, the script given by EXOMETER_CONFIG_PREPROCESS (if any) will be run before exometer does any processing of its own, and the EXOMETER_CONFIG_POSTPROCESS script (if any) will be run after all other processing is complete. Things that could be done in preprocessing: re-targeting a dependency, modifying the list of predefined packages, etc.

Modules

<table width="100%" border="0" summary="list of modules"> <tr><td><a href="https://github.com/Feuerlabs/exometer/blob/master/doc/exometer_netlink.md" class="module">exometer_netlink</a></td></tr> <tr><td><a href="https://github.com/Feuerlabs/exometer/blob/master/doc/exometer_report_amqp.md" class="module">exometer_report_amqp</a></td></tr> <tr><td><a href="https://github.com/Feuerlabs/exometer/blob/master/doc/exometer_report_graphite.md" class="module">exometer_report_graphite</a></td></tr> <tr><td><a href="https://github.com/Feuerlabs/exometer/blob/master/doc/exometer_report_opentsdb.md" class="module">exometer_report_opentsdb</a></td></tr> <tr><td><a href="https://github.com/Feuerlabs/exometer/blob/master/doc/exometer_report_snmp.md" class="module">exometer_report_snmp</a></td></tr> <tr><td><a href="https://github.com/Feuerlabs/exometer/blob/master/doc/exometer_report_statsd.md" class="module">exometer_report_statsd</a></td></tr></table>