Awesome
ACSC
Automatic extrinsic calibration for non-repetitive scanning solid-state LiDAR and camera systems.
System Architecture
1. Dependency
Tested with Ubuntu 16.04 64-bit and Ubuntu 18.04 64-bit.
-
ROS (tested with kinetic / melodic)
-
Eigen 3.2.5
-
PCL 1.8
-
python 2.X / 3.X
-
opencv-python (>= 4.0)
-
scipy
-
scikit-learn
-
transforms3d
-
pyyaml
-
mayavi (optional, for debug and visualization only)
2. Preparation
2.1 Download and installation
Use the following commands to download this repo.
Notice: the SUBMODULE should also be cloned.
git clone --recurse-submodules https://github.com/HViktorTsoi/ACSC
Compile and install the normal-diff segmentation extension.
cd /path/to/your/ACSC/segmentation
python setup.py install
We developed a practical ROS tool to achieve convenient calibration data collection, which can automatically organize the data into the format in 3.1. We strongly recommend that you use this tool to simplify the calibration process.
It's ok if you don't have ROS or don't use the provided tool, just manually process the images and point clouds into 3.1's format.
First enter the directory of the collection tool and run the following command:
cd /path/to/your/ACSC/ros/livox_calibration_ws
catkin_make
source ./devel/setup.zsh # or source ./devel/setup.sh
File explanation
-
ros/
: The data collection tool directory (A ros workspace); -
configs/
: The directory used to store configuration files; -
calibration.py
: The main code for solving extrinsic parameters; -
projection_validation.py
: The code for visualization and verification of calibration results; -
utils.py
: utilities.
2.2 Preparing the calibration board
We use a common checkerboard as the calibration target.
Notice, to ensure the success rate of calibration, it is best to meet the following requirement, when making and placing the calibration board:
-
The size of the black/white square in the checkerboard should be >= 8cm;
-
The checkerboard should be printed out on white paper, and pasted on a rectangular surface that will not deform;
-
There should be no extra borders around the checkerboard;
-
The checkerboard should be placed on a thin monopod, or suspended in the air with a thin wire. And during the calibration process, the support should be as stable as possible (Due to the need for point cloud integration);
-
When placing the checkerboard on the base, the lower edge of the board should be parallel to the ground;
-
There are not supposed to be obstructions within 3m of the radius of the calibration board.
Checkerboard placement
Sensor setup
3. Extrinsic Calibration
3.1 Data format
The images and LiDAR point clouds data need to be organized into the following format:
|- data_root
|-- images
|---- 000000.png
|---- 000001.png
|---- ......
|-- pcds
|---- 000000.npy
|---- 000001.npy
|---- ......
|-- distortion
|-- intrinsic
Among them, the images
directory contains images containing checkerboard at different placements, recorded by the camera ;
The pcds
directory contains point clouds corresponding to the images, each point cloud is a numpy array, with the shape of N x 4
,
and each row is the x
, y
, z
and reflectance
information of the point;
The distortion
and intrinsic
are the distortion parameters and intrinsic parameters of the camera respectively (will be described in detail in 3.3).
Sample Data
The sample solid state LiDAR point clouds, images and camera intrinsic data can be downloaded (375.6 MB) on:
Google Drive | BaiduPan (Code: fws7)
If you are testing with the provided sample data, you can directly jump to 3.4.
3.2 Data collection for your own sensors
First, make sure you can receive data topics from the the Livox LiDAR (
sensor_msgs.PointCloud2
) and Camera ( sensor_msgs.Image
);
Run the launch file of the data collection tool:
mkdir /tmp/data
cd /path/to/your/ACSC/ros/livox_calibration_ws
source ./devel/setup.zsh # or source ./devel/setup.sh
roslaunch calibration_data_collection lidar_camera_calibration.launch \
config-path:=/home/hvt/Code/livox_camera_calibration/configs/data_collection.yaml \
image-topic:=/camera/image_raw \
lidar-topic:=/livox/lidar \
saving-path:=/tmp/data
Here, config-path
is the path of the configuration file, usually we use configs/data_collection.yaml
, and leave it as default;
The image-topic
and lidar-topic
are the topic names that we receive camera images and LiDAR point clouds, respectively;
The saving-path
is the directory where the calibration data is temporarily stored.
After launching, you should be able to see the following two interfaces, which are the real-time camera image, and the birdeye projection of LiDAR.
If any of these two interfaces is not displayed properly, please check yourimage-topic
and lidar-topic
to see if the data can be received normally.
Place the checkerboard, observe the position of the checkerboard on the LiDAR birdeye view interface, to ensure that it is within the FOVof the LiDAR and the camera.
Then, press <Enter>
to record the data; you need to wait for a few seconds, after the point cloud is collected and integrated, and the screen prompts that the data recording is complete, change the position of the checkerboard and continue to record the next set of data.
To ensure the robustness of the calibration results, the placement of the checkerboard should meet the following requirement:
-
The checkerboard should be at least 2 meters away from the LiDAR;
-
The checkerboard should be placed in at least 6 positions, which are the left, middle, and right sides of the short distance (about 4m), and the left, middle, and right sides of the long distance (8m);
-
In each position, the calibration plate should have 2~3 different orientations.
When all calibration data is collected, type Ctrl+c
in the terminal to close the calibration tool.
At this point, you should be able to see the newly generated data folder named with saving-path
that we specified, where images are saved in images
, and point clouds are saved in pcds
:
3.3 Camera intrinsic parameters
There are many tools for camera intrinsic calibration, here we recommend using the Camera Calibrator App in MATLAB, or the Camera Calibration Tools in ROS, to calibrate the camera intrinsic.
Write the camera intrinsic matrix
fx s x0
0 fy y0
0 0 1
into the intrinsic
file under data-root
. The format should be as shown below:
Write the camera distortion vector
k1 k2 p1 p2 k3
into the distortion
file under data-root
. The format should be as shown below:
3.4 Extrinsic Calibration
When you have completed all the steps in 3.1 ~ 3.3, the data-root
directory should contain the following content:
If any files are missing, please confirm whether all the steps in 3.1~3.3 are completed.
Modify the calibration configuration file in directory config
, here we take sample.yaml as an example:
-
Modify the
root
underdata
, to the root directory of data collected in 3.1~3.3. In our example,root
should be/tmp/data/1595233229.25
; -
Modify the
chessboard
parameter underdata
, changeW
andH
to the number of inner corners of the checkerboard that you use (note that, it is not the number of squares, but the number of inner corners. For instance, for the checkerboard in 2.2, W= 7, H=5); ModifyGRID_SIZE
to the side length of a single little white / black square of the checkerboard (unit is m);
Then, run the extrinsic calibration code:
python calibration.py --config ./configs/sample.yaml
After calibration, the extrinsic parameter matrix will be written into the parameter/extrinsic
file under data-root
.
4. Validation of result
After extrinsic calibration of step 3, run projection_projection.py
to check whether the calibration is accurate:
python projection_validation.py --config ./configs/sample.yaml
It will display the point cloud reprojection to the image with solved extrinsic parameters, the RGB-colorized point cloud, and the visualization of the detected 3D corners reprojected to the image.
Note that, the 3D point cloud colorization results will only be displayed if
mayavi
is installed.
Reprojection of Livox Horizon Point Cloud
Reprojection Result of Livox Mid100 Point Cloud
Reprojection Result of Livox Mid40 Point Cloud
Colorized Point Cloud
Detected Corners
Appendix
I. Tested sensor combinations
No. | LiDAR | Camera | Chessboard Pattern |
---|---|---|---|
1 | LIVOX Horizon | MYNTEYE-D 120 | 7x5, 0.08m |
2 | LIVOX Horizon | MYNTEYE-D 120 | 7x5, 0.15m |
3 | LIVOX Horizon | AVT Mako G-158C | 7x5, 0.08m |
4 | LIVOX Horizon | Pointgrey CM3-U3-31S4C-CS | 7x5, 0.08m |
5 | LIVOX Mid-40 | MYNTEYE-D 120 | 7x5, 0.08m |
6 | LIVOX Mid-40 | MYNTEYE-D 120 | 7x5, 0.15m |
7 | LIVOX Mid-40 | AVT Mako G-158C | 7x5, 0.08m |
8 | LIVOX Mid-40 | Pointgrey CM3-U3-31S4C-CS | 7x5, 0.08m |
9 | LIVOX Mid-100 | MYNTEYE-D 120 | 7x5, 0.08m |
10 | LIVOX Mid-100 | MYNTEYE-D 120 | 7x5, 0.15m |
11 | LIVOX Mid-100 | AVT Mako G-158C | 7x5, 0.08m |
12 | LIVOX Mid-100 | Pointgrey CM3-U3-31S4C-CS | 7x5, 0.08m |
13 | RoboSense ruby | MYNTEYE-D 120 | 7x5, 0.08m |
14 | RoboSense ruby | AVT Mako G-158C | 7x5, 0.08m |
15 | RoboSense ruby | Pointgrey CM3-U3-31S4C-CS | 7x5, 0.08m |
16 | RoboSense RS32 | MYNTEYE-D 120 | 7x5, 0.08m |
17 | RoboSense RS32 | AVT Mako G-158C | 7x5, 0.08m |
18 | RoboSense RS32 | Pointgrey CM3-U3-31S4C-CS | 7x5, 0.08m |
II. Paper
ACSC: Automatic Calibration for Non-repetitive Scanning Solid-State LiDAR and Camera Systems
@misc{cui2020acsc,
title={ACSC: Automatic Calibration for Non-repetitive Scanning Solid-State LiDAR and Camera Systems},
author={Jiahe Cui and Jianwei Niu and Zhenchao Ouyang and Yunxiang He and Dian Liu},
year={2020},
eprint={2011.08516},
archivePrefix={arXiv},
primaryClass={cs.CV}
}
III. Known Issues
Updating...