FoxESS BMS to Battery RS485 Protocol between FoxESS V1 BMS and V1 HV2600 Battery

RS485 @ 115,200 baud, N,8,1 - Big Endian

This is an early work (in progress) in decoding the messages between the FoxESS BMS and HV Batteries

Basic Protocol

The RS485 should be configured with 115,200 baud, N, 8, 1

This mostly documents the running state, the startup is documented towards the end - at startup the BMS checks the packs for operation response, and then requests battery serial numbers and pack status before it moves into normal state.

Notes:

From my testing the battery packs report their own soc and kw remaining however the BMS largely ignores these and favours its own calculation based on cell voltages, watt counters and some temperature compensation - I would say this is wise as the packs often report incorrect stats, for example the battery pack can report an soc of 7% yet have a positive kw remaining and it's cell volts confirms these are wrong, likely the battery slave has some soc drift problems which the BMS corrects for.

The 'total' pack voltage the battery reports is not that reliable, if you sum the mV of all the cells in the pack you often get a slightly different number (from my tests I trust the cell mV and not the reported pack voltage - the differences are small, but with LFP small differences are significant)

On the HV2600 pack there are 16 LifePo4 cells with a typical in operation voltage range of 3.1 to 3.55V, each cell reports its own voltage (16 cell voltages), however there are only 8 temperature probes - I believe (from deductionrather than a physical teardown) that the cells are grouped into 2's sharing a single temperature probe and an active balancer circuit. [Note I would be grateful if anyone ever gets the chance to postmortem a pack they check this, or send it to me so I can review the design].

The individual packs balance their own cells, the BMS broadcasts the pack high mV and low mV to all packs so they know what the 'pack' range is for them to try and close the gap with their balance circuits. The active balance circuitry appears (from observation of current flow, not circuit design) to be capable of moving charge between cells at between 200mA and 600mA (depending on charge or discharge balance). This suggests a badly balanced pack could take some considerable time before pack balance can be achieved - and so the best way to achieve alignment is to limit the charge current - this will take the pack longer to charge, but it allows the individual pack more time to calibrate.

The BMS appears to be in command of the charge request, I have run the batteries to BMS minsoc (some packs were reporting well below minsoc, but their cell voltages indicated they were wrong) at which point the discharge was cut, and a force charge occurred - there were no messages within the pack to request this other than normal status messages, this charge request occurs from the BMS to inverter on CANBUS and results in the inverter enabling it's charger at a low charge rate (usually ~1kw).

Messages

Unlike other BMS<>Battery protocols where the messages have an [SOI]...[EOI] this protocol differs somewhat..

As a general rule the BMS sends a 10 byte message which contains the [pack_id],[function],[length],[command bytes 1,2,3], followed by a 2 byte checksum and <0d>,<0a>.

BMS Sends -

<01>,<03>,<00>,<00>,<00>,<08>,<44>,<0C>,<0D>,<0A>

which is [Pack_id=1],[Function=3],[Length=0][CMD1=0],[CMD2=0],[CMD3=8],[CSUM Bytes 1=44,2=0C],[EOI=0D,0A]

When (Length)= 0 this is a request for data.

Received message - The <pack_id> requested will respond with its data as -

<01>,<03>,<10>,<00>,<00>,<67>,<E2>,<F7>,<B5>,<00>,<4C>,<0D>,<00>,<0C>,<FD>,<0B>,<0E>,<0A>,<D2>,<27>,<41>,<0D>,<0A>

which is [Pack_id=1],[Function=3],[Length=x10][Data Bytes 1...Length],[CSUM Bytes 1=27,2=41],[EOI=0D,0A]

Occasionally the BMS will send a broadcast message with pack_id = 0

> 00,8C,FD,D4,81,0D,0A

The packs do not respond to this message

This is the BMS instrutcing the packs what the minimum cell voltage is across the pack. The command data for this example is 8C, FD the first byte '8C' the '8' is number of packs, the 'C' is the msb and the 'FD' is the lsb i.e. as it is big endian the value is 3,313mV

The BMS breaks the basic rule (terminated by 0d,0a) by sending a message that does not have the 0d,0a terminator, this appears to be an instruction to all the packs as well as a keep alive timer. This is a sample of 3 of the messages -

> 01,03,02,AB,02,81,15,15,92,F5 

This is [1],[3],[02,AB,02,81],[15,15],[CSUM,CSUM] - command is currently unknown

> 01,03,00,5E,00,92,11,11,EC,7C - Pack status

The data is [00,5E,00,92] where 00,5E is SINT16 Current Sense (-0.94A),  00,92 is UINT16 Highest Cycles Count (94 cycles)

> 01,03,0D,28,0D,1F,13,13,36,8C - Pack cell volts High and Low

The data is [0D,28,0D,1F] where 0D,28 is UINT16 Pack Highest mV (3355mV) 0D,1F is UINT16 Pack lowest mV (3346mV)

It is never replied to, it does have a valid checksum with a small difference in calculation (see checksum section below)

BMS Commands

The BMS send command is comprised of three command codes,

<Command 1>,<Command 2>, <Command 3>

they are tabulated here

Command 1Command 2Command 3Notes
220005Send pack statistics
080009Send pack cell mV 1-9
110009Send pack cell mV 10-18
1A0008Send pack temps
000008Send pack status
230001Request pack state (startup only)
E00009Request pack serial number (startup only)

each message sequence is sent approx every 100mS, gaps between messages are approx 30mS - so each pack sequence is approx 0.5S apart

Command by Command review

BMS command <22,00,05> Pack Stats

the send message to pack_1 looks like this -

01,03,00,22,00,05,25,C3,0D,0A

and the pack_1 response is this -

01,03,0A,00,00,01,00,58,33,00,0B,20,82,04,05,0D,0A

The Length is 0A (decimal 10), the data begins at byte 4 for 10 bytes, followed by checksum of 04,05 and terminated by 0d,0a

The data packet is <00,00,01,00,58,33,00,0B,20,82>

So far all 16 bit integers have been the first byte is most significant.

the data packet contains the following information

Byte1Byte2Byte3Byte4Byte5Byte6Byte7,8Byte9Byte10Notes
<0x00><0x00>Pack_id<0x00>SoCFlags?Cyclesf/w_verbatt_type
0x000x000x010x000x580x330x00,0x0B0x200x82Received packet
0000010088%00110011Cycles=112.082Decoded info, SoC=88%, Flags=00110011, ver 2.0, battery_type=(0x82=V1HV2600, 0x84=V2), Cycles = 11

Notes:

  Cycles Byte7=msb, Byte8=lsb - diviser 1 e.g (0x00*256)+0x90= 144 cycles

  f/w ver Byte9 top nibble is major, bottom nibble is minor version so 0x1F is 1.15 and 0x20 is 2.0

  batt_type  Byte10=0x82 is HV2600 V1, 0x83 is ECS4100 v1, 0x84 is HV2600 v2

  Flags, Byte6 assumed to be charge, discharge, balance etc.. - more testing required.

BMS command <08,00,09> Cell mV 1-9

the send message to pack_8 looks like this -

01,03,00,08,00,09,04,0E,0D,0A

and the pack_8 response is this -

01,03,12,0C,FD,0C,FD,0C,FE,0C,FD,0C,FD,0C,FD,0C,FD,0C,FD,0C,FD,20,F1,0D,0A

The Length is 12 (decimal 18), the data begins at byte 4 for 18 bytes, followed by checksum of 20,F1 and terminated by 0d,0a

The data packet is <0C,FD,0C,FD,0C,FE,0C,FD,0C,FD,0C,FD,0C,FD,0C,FD,0C,FD>

So far all 16 bit integers have seen the first byte as most significant.

the data packet contains the following information

Byte1, 2Byte3,4Byte5,6Byte7,8Byte9,10Byte11,12Byte13,14Byte15,16Byte17,18Notes
(Cell_1mV)(Cell_2mV)(Cell_3mV)(Cell_4mV)(Cell_5mV)(Cell_6mV)(Cell_7mV)(Cell_8mV)(Cell_9mV)
0x0C,0xFD0x0C,0xFD0xOC,0xFE0x0C,0xFD0x0C,0xFD0x0C,0xFD0x0C,0xFD0x0C,0xFD0x0C,0xFD
3325mV3325mV3326mV3325mV3325mV3325mV3325mV3325mV3325mV

Notes:

  Cell mV, 1st byte=msb, 2nd byte4=lsb, diviser = 1 e.g 0x0C,0xFE = 3326mV

BMS command <11,00,09> Cell mV 10-18

the send message to pack_1 looks like this -

01,03,00,11,00,09,D5,C9,0D,0A

and the pack_1 response is this -

01,03,12,0C,FE,0C,FD,0C,FE,0C,FC,0C,FC,0C,FC,0C,FB,00,00,00,00,17,8C,0D,0A

The Length is 12 (decimal 18), the data begins at byte 4 for 18 bytes, followed by checksum of 17,8C and terminated by 0d,0a

The data packet is <0C,FE,0C,FD,0C,FE,0C,FC,0C,FC,0C,FC,0C,FB,00,00,00,00>

So far all 16 bit integers have been the first byte is most significant.

the data packet contains the following information

Byte1, 2Byte3,4Byte5,6Byte7,8Byte9,10Byte11,12Byte13,14Byte15,16Byte17,18Notes
(C10mV)(C11mV)(C12mV)(C13mV)(C14mV)(C15mV)(C16mV)(C17mV)(C18mV)Cells 17,18
0x0C,0xFE0x0C,0xFD0xOC,0xFE0x0C,0xFC0x0C,0xFC0x0C,0xFC0x0C,0xFB0x00,0x000x00,0x00not fitted
3326mV3325mV3326mV3324mV3324mV3324mV3323mVn/an/aon HV2600

BMS command <00,00,08> Pack Status

the send message to pack_1 looks like this -

01,03,00,00,00,08,44,0C,0D,0A

and the pack_1 response is this -

01,03,10,00,00,67,E7,F7,DC,00,ED,0C,FE,0C,FB,0A,6E,0A,32,58,27,0D,0A

The Length is 10 (decimal 16), the data begins at byte 4 for 16 bytes, followed by checksum of 58,27 and terminated by 0d,0a

The data packet is <00,00,67,E7,F7,DC,00,ED,0C,FE,0C,FB,0A,6E,0A,32>

So far all 16 bit integers have been the first byte is most significant.

the data packet contains the following information

Byte1Byte2Byte3,4Byte5Byte6Byte7,8Byte9,10Byte11,12Byte13,14Byte15,16Notes
<0x00><0x00>VoltsHWkWRAmpsHimVLomVHiCellTempLoCellTemp
0x000x000x67,0xE70xF70xDC0x00,0xED0x0C,0xFE0x0C,0xFB0x0A,0x6E0x0A,0x32
000053.198V002.2kwH-2.37A3326332326.70C26.10C

Notes:

  Volts Byte3=msb, Byte4=lsb - then double value, diviser 0.001 e.g (0x67*256)+0xE7= (26,599 * 2)/1000 = 53.198V

  kWR   Byte6 diviser, convert to decimal, diviser = 0.01 e.g (0xDC) = 220/100 = 2.2kwh

  Amps  Byte7=msb,Byte8=lsb signed, diviser = 0.01 0x00,0xED = 237/100 = -2.37A (discharge), >32768=charge

  Hi/LomV, 1st byte=msb, 2nd byte4=lsb, diviser = 1 e.g 0x0C,0xFE = 3326mV

  Hi/LoCellTemp 1st byte=msb, 2nd byte4=lsb, diviser = 0.01 e.g 0x0A,0x6E = 26.70C

  HW    Byte5 looks to be either hardware version or encoded manufacture date.

Checksum

The checksum is calculate using all bytes of the message (except the checksum and terminator 0a 0d) using CRC16 (modbus) Big Endian

03,03,00,08,00,09,05,EC,0D,0A e.g.030300080009 = 0x05EC

04,03,00,08,00,09,04,5B,0D,0A = 0x045B

07,03,00,08,00,09,04,68,0D,0A = 0x0468

08,03,00,08,00,09,04,97,0D,0A = 0x0497

08,03,12,0C,FC,0C,FD,0C,FD,0C,FC,0C,FC,0C,FE,0C,FE,0C,FE,0C,FE,23,56,0D,0A = 0x2356

Note - The weird BMS message has a checksum but it calculates from the second byte of the message

(1) 1,3,0,0,0,95,11,11,F4,70 - checksum calculation is 03000000951111 = 0xF470 (2) 1,3,0c,df,0c,d3,13,13,3,4b - checksum calculation is 030cdf0cd31313 = 0x034b (3) 1,3,2,76,2,61,15,15,7f,10

This appears to be an instruction from the BMS to set charge/balance flags - it is unclear at this moment as the message seems static apart from 2 bytes of message 3, work continues....

STARTUP PROCESS

When the BMS is starting up, the following procedure is observed

BMS sends the following commands (with no response)

-> 00,01,01,[CSUM],[0D0A]

-> 00,01,01,[CSUM],[0D0A]

-> 00,01,01,[CSUM],[0D0A]

-> 00,00,03,[CSUM],[0D0A]

-> 00,00,03,[CSUM],[0D0A]

-> 00,00,03,[CSUM],[0D0A]

This may be part of the pack learning/allocating the pack_id's as battery addressing on the HV2600's is always fixed with batteries nearest the BMS running 1,2,3,4,5... as it gets further away (assume the master/slave ports are involved in this in some way)

Then the BMS sends

-> FF, 10, 00,23, 00, 01, 01, 00, 8B, 59, 0D, 0A ('FF' as pack is 'all' broadcast - the command is this pack functional? )

[pack_id], [command 10],[len=0],[cid1],[23],[cid2 0],[cid3 1],[pack_id 1],[0x00],[CSUM],[0D0A]

Response from pack 1 (pack_id from message)

<- 01,10,00,23,00, 04, 30, 0D, 0A (pack is operational, no response is not)

BMS repeats ( for (pack_id = 1; pack_id <= 8; ++pack_id) )

-> FF, 10, 00, 23, 00, 01,[pack_id], 00, [CSUM], [0D0A]

Response from pack_id's

<- [pack_id],10,00,23,00, [CSUM], [0D0A]

Then BMS sends

-> FF, 03, 00, 00, 00, 08, [CSUM], [0D0A]

-> FF, 03, 00, 00, 00, 08, [CSUM], [0D0A]

' there is no response from packs to this message - I assume it means next command coming is status '00, 00, 08'

Then BMS Sends pack statistic requests

-> 01, 03, 00, 00, 00, 08, [CSUM], [0D0A]

Response from pack 1

<- 01,03,[LEN],[DATA....*LEN], [CSUM], [0D0A]

(this is the normal response to request for pack statistics)

BMS repeats ( for (pack_id = 1; pack_id <= 8; ++pack_id) )

Response from pack_id's

[pack_id],03,[LEN],[DATA....*LEN], [CSUM], [0D0A]

Then BMS Sends pack statistic and status requests in groups

-> 01, 03, 00, 00, 00, 08, [CSUM], [0D0A]

<- [pack_id],03,[LEN],[DATA....*LEN], [CSUM], [0D0A]

-> 01, 03, 00, 22, 00, 05, [CSUM], [0D0A]

<- [pack_id],03,[LEN],[DATA....*LEN], [CSUM], [0D0A]

BMS repeats group 00,00,08 then 22,00,05 ( for (pack_id = 1; pack_id <= 8; ++pack_id) )

each pack responds

Then BMS moves on to information request

-> 01, 03, 00, E0, 00, 09, [CSUM], [0D0A] ' send serial number

<- 01, 03, [LEN=18], [DATA... * LEN], [CSUM], [0D0A]

where data is ascii serial number i.e. if first 5 bytes are 36, 30, 32, 48, 32, 36, 32, the serial number is '602H262xxxx'

BMS repeats ( for (pack_id = 1; pack_id <= 8; ++pack_id) )

AT THIS POINT THE RUNNING STATE IS NORMAL i.e. normal cyclical polling of packs

Disclaimer: Any information on this wiki is informal advice, and is not supported nor endorsed by FoxESS. There is no warranty expressed or implied: you take sole responsibility for everything you do with this information and your equipment. There is no warranty to the accuracy of the content, nor any affiliation, or in any way a connection to FoxESS Co. Ltd